The Invisible Force
★Exhibit Content: Lenz's Law ★Interaction: Electromechanical Interaction ★Operation: Press the "Start" button and observe the movement of the aluminum ring on the metal rod. ★Exhibit Description: Through electromechanical interaction, this exhibit allows visitors to operate it themselves, deepening participants' understanding of electromagnetic induction. The main body of the exhibit consists of a circular platform, start button, coil, metal rod, aluminum ring, acrylic cover, etc. The aluminum ring is fitted on the cylinder and has a lightweight coil attached, forming a closed circuit. When the visitor presses the start button, current is generated. When a coil with many turns momentarily passes a strong current, it produces a sudden magnetic field change, and the aluminum ring placed above the coil also generates a strong induced electromotive force. Because the aluminum ring is a closed conductor, a strong current is generated, which in turn produces a strong magnetic field. Since this magnetic field repels the magnetic field generated by the coil, the aluminum ring jumps up high. ★Scientific Principle: At the moment the button is pressed, when the coil momentarily passes a strong current, it produces a sudden magnetic field change, and the aluminum ring placed above the coil also generates a strong induced electromotive force. Because the aluminum ring is a closed conductor, a strong current is generated, which in turn produces a strong magnetic field. Since this magnetic field repels the magnetic field generated by the coil, the aluminum ring jumps up high. The greater the coil current or the faster the current changes, and the smaller the resistance of the aluminum ring, the greater the repulsive force between them.
Options
- Φ0.8*1.2m · Style 1 Φ0.8*1.2mDimensions: Φ0.8*1.2m Brand: KexMall Model: PopsciCat-ElectroMagnetic-015 1. Materials: ① Platform: frame 2mm cold-rolled sheet, enclosure 2.0mm cold-rolled sheet, surface baked paint ② Tabletop: Kelesi artificial stone, thickness ≧12mm, with flame-retardant board underneath ③ Instruction sign: 5mm acrylic UV printing ④ Maintenance door: 2.0mm cold-rolled sheet surface baked paint ⑤ Protective cover: transparent acrylic + custom-colored acrylic as needed ⑥ Demonstration device support: acrylic + 304 stainless steel ⑦ Electrical control box: cold-rolled sheet baked paint enclosure, containing control circuit, switching power supply, circuit breaker, terminal blocks, etc. Main configuration: ① Electrical control: electrical logic control system, equipped with Guanjian® K1 type PLC controller with protection specially for science exhibits ② Switching power supply: AC-DCS-60-12/24 input AC100-240V, 50/60Hz, output power 60W ③ Button: self-reset 22mm stainless steel metal button with ring light; LED voltage not higher than 12V 3. Installation requirements: ① Power requirement: AC100-240V, 50/60Hz300W (standard three-wire socket) ② Installation base: place directly ③ Entry passage: door frame size (width×height) ≧1.0m×1.8m, continuous turning interval ≧1.0m ④ Maintenance access: not required
★Exhibit Content: Lenz's Law ★Interaction: Electromechanical Interaction ★Operation: Press the "Start" button and observe the movement of the aluminum ring on the metal rod. ★Exhibit Description: Through electromechanical interaction, this exhibit allows visitors to operate it themselves, deepening participants' understanding of electromagnetic induction. The main body of the exhibit consists of a circular platform, start button, coil, metal rod, aluminum ring, acrylic cover, etc. The aluminum ring is fitted on the cylinder and has a lightweight coil attached, forming a closed circuit. When the visitor presses the start button, current is generated. When a coil with many turns momentarily passes a strong current, it produces a sudden magnetic field change, and the aluminum ring placed above the coil also generates a strong induced electromotive force. Because the aluminum ring is a closed conductor, a strong current is generated, which in turn produces a strong magnetic field. Since this magnetic field repels the magnetic field generated by the coil, the aluminum ring jumps up high. ★Scientific Principle: At the moment the button is pressed, when the coil momentarily passes a strong current, it produces a sudden magnetic field change, and the aluminum ring placed above the coil also generates a strong induced electromotive force. Because the aluminum ring is a closed conductor, a strong current is generated, which in turn produces a strong magnetic field. Since this magnetic field repels the magnetic field generated by the coil, the aluminum ring jumps up high. The greater the coil current or the faster the current changes, and the smaller the resistance of the aluminum ring, the greater the repulsive force between them.
- Φ0.8*1.2m · Style 2 Φ0.8*1.2mDimensions: Φ0.8*1.2m Brand: KexMall Model: PopsciCat-ElectroMagnetic-016 1. Materials: ① Platform: frame 2mm cold-rolled sheet, enclosure 2.0mm cold-rolled sheet, surface baked paint ② Tabletop: Kelesi artificial stone, thickness ≧12mm, with flame-retardant board underneath ③ Instruction sign: 5mm acrylic UV printing ④ Maintenance door: 2.0mm cold-rolled sheet surface baked paint ⑤ Protective cover: transparent acrylic + custom-colored acrylic as needed ⑥ Demonstration device support: acrylic + 304 stainless steel ⑦ Electrical control box: cold-rolled sheet baked paint enclosure, containing control circuit, switching power supply, circuit breaker, terminal blocks, etc. Main configuration: ① Electrical control: electrical logic control system, equipped with Guanjian® K1 type PLC controller with protection specially for science exhibits ② Switching power supply: AC-DCS-60-12/24 input AC100-240V, 50/60Hz, output power 60W ③ Button: self-reset 22mm stainless steel metal button with ring light; LED voltage not higher than 12V 3. Installation requirements: ① Power requirement: AC100-240V, 50/60Hz300W (standard three-wire socket) ② Installation base: place directly ③ Entry passage: door frame size (width×height) ≧1.0m×1.8m, continuous turning interval ≧1.0m ④ Maintenance access: not required
★Exhibit Content: Lenz's Law ★Interaction: Electromechanical Interaction ★Operation: Press the "Start" button and observe the movement of the aluminum ring on the metal rod. ★Exhibit Description: Through electromechanical interaction, this exhibit allows visitors to operate it themselves, deepening participants' understanding of electromagnetic induction. The main body of the exhibit consists of a circular platform, start button, coil, metal rod, aluminum ring, acrylic cover, etc. The aluminum ring is fitted on the cylinder and has a lightweight coil attached, forming a closed circuit. When the visitor presses the start button, current is generated. When a coil with many turns momentarily passes a strong current, it produces a sudden magnetic field change, and the aluminum ring placed above the coil also generates a strong induced electromotive force. Because the aluminum ring is a closed conductor, a strong current is generated, which in turn produces a strong magnetic field. Since this magnetic field repels the magnetic field generated by the coil, the aluminum ring jumps up high. ★Scientific Principle: At the moment the button is pressed, when the coil momentarily passes a strong current, it produces a sudden magnetic field change, and the aluminum ring placed above the coil also generates a strong induced electromotive force. Because the aluminum ring is a closed conductor, a strong current is generated, which in turn produces a strong magnetic field. Since this magnetic field repels the magnetic field generated by the coil, the aluminum ring jumps up high. The greater the coil current or the faster the current changes, and the smaller the resistance of the aluminum ring, the greater the repulsive force between them.
- Φ0.8*2.2m Φ0.8*2.2mDimensions: Φ0.8*2.2m Brand: KexMall Model: PopsciCat-ElectroMagnetic-017 1. Materials: ① Platform: frame 2mm cold-rolled sheet, enclosure 2.0mm cold-rolled sheet, surface baked paint ② Tabletop: Kelesi artificial stone, thickness ≧12mm, with flame-retardant board underneath ③ Instruction sign, graphic panel: 5mm acrylic UV printing ④ Maintenance door: 2.0mm cold-rolled sheet surface baked paint ⑤ Protective cover: transparent acrylic + orange acrylic ⑥ Guide rod: 304 stainless steel ⑦ Electrical control box: cold-rolled sheet baked paint enclosure, containing control circuit, switching power supply, circuit breaker, terminal blocks, etc. 2. Main configuration: ① Electrical control: electrical logic control system, equipped with Guanjian® K2 type PLC controller with protection specially for science exhibits ② Button: self-reset 22mm stainless steel metal button with ring light; LED voltage not higher than 12V ③ High-voltage power generator: TH5-A neon transformer. Input voltage: AC100-240V, 50/60Hz Rated output voltage: 15KV Input current at rated load: 2A Rated output current: 30mA Rated capacity: 450VA Insulation class: E 3. Installation requirements: ① Power requirement: AC100-240V, 50/60Hz500W (standard three-wire socket) ② Installation base: place directly ③ Entry passage: door frame size (width×height) ≧1.0m×2.3m, continuous turning interval ≧2m ④ Maintenance access: not required
★Exhibit Content: Lenz's Law ★Interaction: Electromechanical Interaction ★Operation: Press the "Start" button and observe the movement of the aluminum ring on the metal rod. ★Exhibit Description: Through electromechanical interaction, this exhibit allows visitors to operate it themselves, deepening participants' understanding of electromagnetic induction. The main body of the exhibit consists of a circular platform, start button, coil, metal rod, aluminum ring, acrylic cover, etc. The aluminum ring is fitted on the cylinder and has a lightweight coil attached, forming a closed circuit. When the visitor presses the start button, current is generated. When a coil with many turns momentarily passes a strong current, it produces a sudden magnetic field change, and the aluminum ring placed above the coil also generates a strong induced electromotive force. Because the aluminum ring is a closed conductor, a strong current is generated, which in turn produces a strong magnetic field. Since this magnetic field repels the magnetic field generated by the coil, the aluminum ring jumps up high. ★Scientific Principle: At the moment the button is pressed, when the coil momentarily passes a strong current, it produces a sudden magnetic field change, and the aluminum ring placed above the coil also generates a strong induced electromotive force. Because the aluminum ring is a closed conductor, a strong current is generated, which in turn produces a strong magnetic field. Since this magnetic field repels the magnetic field generated by the coil, the aluminum ring jumps up high. The greater the coil current or the faster the current changes, and the smaller the resistance of the aluminum ring, the greater the repulsive force between them.
- 1.0*0.8*2.2m 1.0*0.8*2.2mDimensions: 1.0*0.8*2.2m Brand: KexMall Model: PopsciCat-ElectroMagnetic-018 1. Materials: ① Platform: frame 2mm cold-rolled sheet, enclosure 2.0mm cold-rolled sheet, surface baked paint ② Tabletop: Kelesi artificial stone, thickness ≧12mm, with flame-retardant board underneath ③ Instruction sign, graphic panel: 5mm acrylic UV printing ④ Maintenance door: 2.0mm cold-rolled sheet surface baked paint ⑤ Protective cover: transparent acrylic + orange acrylic ⑥ Guide rod: 304 stainless steel ⑦ Electrical control box: cold-rolled sheet baked paint enclosure, containing control circuit, switching power supply, circuit breaker, terminal blocks, etc. 2. Main configuration: ① Electrical control: electrical logic control system, equipped with Guanjian® K2 type PLC controller with protection specially for science exhibits ② Button: self-reset 22mm stainless steel metal button with ring light; LED voltage not higher than 12V ③ High-voltage power generator: TH5-A neon transformer. Input voltage: AC100-240V, 50/60Hz Rated output voltage: 15KV Input current at rated load: 2A Rated output current: 30mA Rated capacity: 450VA Insulation class: E 3. Installation requirements: ① Power requirement: AC100-240V, 50/60Hz500W (standard three-wire socket) ② Installation base: place directly ③ Entry passage: door frame size (width×height) ≧1.0m×2.3m, continuous turning interval ≧2m ④ Maintenance access: not required
★Exhibit Content: Lenz's Law ★Interaction: Electromechanical Interaction ★Operation: Press the "Start" button and observe the movement of the aluminum ring on the metal rod. ★Exhibit Description: The exhibit mainly consists of a ring body, coil, stainless steel cylinder, transparent protective cover, and button. A coil is installed at the bottom of the stainless steel cylinder on the platform, and a metal ring is fitted on the stainless steel cylinder. The visitor selects the button representing no current, and voltage is applied to both ends of the coil, generating a magnetic field. Since the metal ring is a closed metal conductor, an induced current is generated in the ring body, simultaneously producing a magnetic field. The interaction of the magnetic fields causes the ring body to move upward along the stainless steel cylinder. ★Scientific Principle: A coil is wound around a conductor, and an alternating current is passed through the coil, generating an alternating magnetic field. In the circumferential direction of the conductor, an induced electromotive force is generated, forming an induced current. The induced current generates a magnetic field around it, which is opposite in direction to the coil's magnetic field, so the metal ring pops up due to like-pole repulsion. At the moment the button is pressed, when the coil momentarily passes a strong current, it produces a sudden magnetic field change, and the aluminum ring placed above the coil also generates a strong induced electromotive force. Because the aluminum ring is a closed conductor, a strong current is generated, which in turn produces a strong magnetic field. Since this magnetic field repels the magnetic field generated by the coil, the aluminum ring jumps up high. The greater the coil current or the faster the current changes, and the smaller the resistance of the aluminum ring, the greater the repulsive force between them.
Review
Principle Display: ★★★★ Interaction Effect: ★★★ Ease of Installation: ★★★★★ Durability: ★★★★ Overall Rating: ★★★★